| Product | Type | Plates | Max Flow |
|---|---|---|---|
| Heat Exchanger | Brazed Plate | 90 | 74.41 GPM |
Note: Unit pictured is representative of standard unit and may not exactly depict p/n B16Hx90/1P-SC-S 4x1 1/4"(27) as shown on this page.
This is the 90-plate B16: SWEP designation B16Hx90/1P-SC-S 4x1 1/4"(27). Its H plates are the high-theta pattern - the choice when the leaving temperature is tight and the pump has head to spare. Reading the string: /1P is single pass; -SC is 316/316L stainless steel plates joined with copper. The closing S is the pressure class: 31 bar at 155 C. The connection field reads 4x1 1/4"(27). The B16 plate pack measures 376 x 119 mm (14.8 x 4.69 in) on 320 x 63 mm port centres, and by SWEP's published weight formula a 90-plate unit comes to about 12.3 kg (27.1 lb) dry. Maximum flow for the frame is 16.9 m3/h (74.41 GPM); that is a ceiling for the ports, not a duty point. Treat each side as an independent circuit when you ask for a quote: give both flows and what each fluid is.