Hydronic and Process

Water to water, glycol to water, and the isolation duties that keep one loop's pressure, chemistry and static head away from another's.

Request a Quote

Hydronic and Process

Water to water, glycol to water, and the isolation duties that keep one loop's pressure, chemistry and static head away from another's.

Liquid on both sides, no phase change. These duties differ in temperatures, approach and what has to be kept apart - open one for its frames and its usual commissioning faults.

Boiler Isolation

Boiler Isolation:

Approach Costs Boiler Efficiency Directly

  • A boiler isolation exchanger separates the boiler's own water from...
  • Frames that suit the duty
  • Common FAQs answered
Heat Recovery

Heat Recovery:

Buy Approach, Not Capacity

  • Heat recovery is specified on approach temperature and nothing...
  • Frames that suit the duty
  • Common FAQs answered
Glycol Loop Separation

Glycol Loop Separation:

Size on the Actual Concentration

  • A glycol loop and a water loop have different chemistry, different...
  • Frames that suit the duty
  • Common FAQs answered
Free Cooling

Free Cooling:

Size Against the Weather File, Not the Design Day

  • Free cooling rejects building load straight to the cooling tower or...
  • Frames that suit the duty
  • Common FAQs answered
Radiant Floor and Snow Melt

Radiant Floor and Snow Melt:

Expect a Higher Plate Count

  • Radiant and snow melt systems run glycol in the slab and water in the...
  • Frames that suit the duty
  • Common FAQs answered

Hydronic Duty Is Isolation Duty

The Exchanger Is the Boundary

Boiler isolation, glycol separation, free cooling and heat recovery all reduce to the same drawing: two circuits that must exchange heat without mixing. What varies is which side fouls, which side freezes, and how tight an approach the economics demand.

Those three questions, answered honestly, select the frame.

Approach Is Money on Both Sides

On heat recovery the approach IS the payback; on boiler isolation it is return temperature and condensing efficiency. Plate count buys approach, and plate count is most of the price - so the right number comes from the system, not from a margin habit.

Frames for These Duties

SWEP B224 brazed plate heat exchanger

SERIES • 200 TO 400 GPM

SWEP B224

Large ports for data center and district energy duty.

+ Learn More
SWEP B25T brazed plate heat exchanger

SERIES • 18 TO 75 GPM

SWEP B25T

The most widely stocked frame in the range.

+ Learn More
SWEP B85 brazed plate heat exchanger

SERIES • 18 TO 75 GPM

SWEP B85

160 plates on the 526 mm frame, with tighter channels than the B80.

+ Learn More