Refrigerant Duty

Evaporator, condenser, economizer, desuperheater and suction line duty - five jobs that look similar on a schematic and place very different demands on the plate pack.

Request a Quote

Refrigerant Duty

Evaporator, condenser, economizer, desuperheater and suction line duty - five jobs that look similar on a schematic and place very different demands on the plate pack.

Refrigerant on one side makes the exchanger part of the circuit. Pick the role the unit plays to see which frames fit it and what tends to go wrong on first start.

Evaporators

Evaporators:

V-series

  • An evaporator boils refrigerant against water or...
  • Frames that suit the duty
  • Common FAQs answered
Condensers

Condensers:

Gas in at the Top Left, Condensate Out at the Bottom Left

  • A condenser does three jobs in one pack: it desuperheats the...
  • Frames that suit the duty
  • Common FAQs answered
Economizers

Economizers:

Sized on Subcooling, Not Tonnage

  • An economizer is a subcooler that uses part of the refrigerant flow...
  • Frames that suit the duty
  • Common FAQs answered
Desuperheaters

Desuperheaters:

This is the Duty Most Likely to Hit the Braze Ceiling

  • A desuperheater takes the superheat out of compressor discharge gas...
  • Frames that suit the duty
  • Common FAQs answered
Suction Line Exchangers

Suction Line Exchangers:

Low Pressure Drop is the Design Priority

  • A suction line heat exchanger superheats the suction gas while...
  • Frames that suit the duty
  • Common FAQs answered

Refrigerant Duty Is Where Plate Geometry Earns Its Keep

Distribution Decides the Evaporator

A flooded channel transfers heat; a starved one is dead surface. The F, P and V evaporator variants exist because refrigerant has to be metered into every channel, not just the first few - and the distributor at the inlet is what separates them from the plain frame they are built on.

Condensing duty is more forgiving, which is why the single-phase frames carry it directly.

Charge and Pressure Class Frame the Choice

A2L and A3 refrigerants bring charge limits in kilograms, and transcritical CO2 brings 140 bar. Between the asymmetric packs, the AsyMatrix builds and the U pressure class, the range answers both - but the refrigerant has to be on the enquiry for any of it to be quoted right.

Frames for These Duties

SWEP B25T brazed plate heat exchanger

SERIES • 18 TO 75 GPM

SWEP B25T

The most widely stocked frame in the range.

+ Learn More
SWEP B18 brazed plate heat exchanger

SERIES • 18 TO 75 GPM

SWEP B18

U pressure class - 64 to 140 bar, built for transcritical CO2.

+ Learn More
SWEP B8T brazed plate heat exchanger

SERIES • UP TO 18 GPM

SWEP B8T

Nickel-brazed - the copper-free option at small size, for ammonia and aggressive media.

+ Learn More