| Product | Type | Plates | Max Flow |
|---|---|---|---|
| Heat Exchanger | Brazed Plate | 40 | 49.75 GPM |
Note: Unit pictured is representative of standard unit and may not exactly depict p/n B26Hx40/1P-NC-M 9.65+16+2x1"&22U as shown on this page.
B26Hx40/1P-NC-M 9.65+16+2x1"&22U designates a SWEP B26 brazed plate heat exchanger with 40 plates in the pack. Its H plates are the high-theta pattern - the choice when the leaving temperature is tight and the pump has head to spare. The /1P-NC fields read as single pass, with AISI 304 stainless steel plates and a copper braze. The closing M is the pressure class: up to 45 bar at 135 C, fatigue tested. It is catalogued with 9.65+16+2x1"&22U connections. The B26 plate pack measures 376 x 119 mm (14.8 x 4.69 in) on 329 x 72 mm port centres, and by SWEP's published weight formula a 40-plate unit comes to about 6.1 kg (13.4 lb) dry. Maximum flow for the frame is 11.3 m3/h (49.75 GPM); that is a ceiling for the ports, not a duty point. A like-for-like order needs only this string; we reccomend adding the fluids and flows where the system has been altered.