| Product | Type | Plates | Max Flow |
|---|---|---|---|
| Heat Exchanger | Brazed Plate | 24 | 39.63 GPM |
Note: Unit pictured is representative of standard unit and may not exactly depict p/n B25THx24/1P-SC-M as shown on this page.
The B25THx24/1P-SC-M is a 24-plate build of the SWEP B25T. The H plate is the obtuse chevron: it gives the most heat transfer per plate and the most pressure drop, so it suits duties where approach temperature matters more than pump head. Reading the string: /1P is single pass; -SC is 316/316L stainless steel plates joined with copper. The closing M is the pressure class: up to 45 bar at 135 C, fatigue tested. The B25T plate pack measures 526 x 119 mm (20.71 x 4.69 in) on 479 x 72 mm port centres, and by SWEP's published weight formula a 24-plate unit comes to about 6.4 kg (14.1 lb) dry. Maximum flow for the frame is 9 m3/h (39.63 GPM); that is a ceiling for the ports, not a duty point. Check the connection field separately from the plate count: two units can be consistent in every other field and still not pipe up.