SWEP DB310 brazed plate heat exchanger

SWEP DB310

PRODUCT TYPE STYLE MAX FLOW
Heat Exchanger Brazed Plate Copper Brazed 264.17 GPM

Specifications


Configuration & Size

Maximum Plates:
350
Brand:
SWEP

Materials

  • Call for the current build list

Ratings

  • Max Flow: 60 m3/h (264.17 GPM)

SWEP DB310 Brazed Plate Heat Exchangers

High-Pressure True Dual

The SWEP DB310 is a True Dual unit for chillers and heat pumps, optimized for performance with refrigerants. It puts two refrigerant circuits and one water circuit in a single brazed plate pack.

Up to 350 plates and 264.17 GPM. The DB310 is built with up to 350 plates and has a published maximum flow of 60 m3/h (264.17 GPM). Configurations on file run from 50 to 220 plates.

The DB310 is the refrigerant-optimized model of the 300 size. It is published at 49 bar (710 psi) and described as optimized for extreme performance with refrigerants. Do not treat it as a variation of the DB300, whose point is low water pressure drop: the two are different plates built for different priorities, and a swap changes both the refrigerant-side behavior and the water pressure drop the pump sees. On a replacement, match DB310 with DB310. The model is now designated DBD310.

Published at 49 bar (710 psi). That pressure figure is what sets this model apart for high-pressure refrigerants. Materials and connections vary by configuration, so we confirm them against your nameplate.

Reading the designation. A DB310 is ordered as a full string, for example DB310x140. The model number guide decodes each field, and the string off the nameplate - whole or partial - is enough to confirm the build.



SWEP DB310 brazed plate heat exchanger detail

Best used on two-circuit chillers and heat pumps running high-pressure refrigerants.

Request a Quote

SWEP DB310 Applications


outline drawing of the SWEP DB310 showing the A x B plate dimensions and C x D port centres

Confirming Fit on a DB310 Replacement

Take every dimension for a DB310 replacement from the unit being replaced: height, width, plate pack depth and the position of each connection. Connection type and size have to match on both refrigerant circuits and the water side, and depth grows with plate count. Send the nameplate with the measurements so the configuration is confirmed before the order.

Call and talk it through with an engineer: 1-805-484-2992

DB310: Fit, Materials and Limits

Vertically, as with any unit in two-phase duty, so that vapor and liquid separate the way the plate was designed for. Pipe the water counter-current to the refrigerant; that arrangement gives the closest approach, and on a dual unit it applies to both circuits.

Support the unit under the plate pack and support the piping separately so the connections carry no load. A two-compressor machine gives the unit two sources of pulsation. Vibration eliminators and proper line supports protect the braze joints at the connections, which is where fatigue cracks start. See Mounting and Piping.

That depends on the material code stamped on the unit, so read it before deciding. SC means 316/316L plates with copper braze, the general-duty construction for refrigerants with water or glycol.

Whatever the plate, a copper-brazed unit is wrong for ammonia and for deionized water. Chloride-bearing water - chlorinated tower water, brackish or seawater-cooled loops - pits ordinary stainless, and a pinhole on a dual unit means water in a refrigerant circuit. If the water side is anything other than a treated closed loop, tell us what it is. Background is under Plate and Brazing Materials.

The model is built with up to 350 plates. The 18 configurations on file run from 50 to 220 plates and include 50, 90, 130 and 170.

More plates give more surface and more parallel channels, so the refrigerant temperature moves closer to the leaving water temperature and the water pressure drop falls for a given flow. The unit also gets deeper, heavier and holds more refrigerant. The published 264.17 GPM does not rise with plate count, because the ports set it.

DB310 is the model: the True Dual unit of the 310 size. x170 is the number of plates. Nothing in those two fields describes materials, rating or connections.

Those come next on a full nameplate - pass arrangement after a slash, then a material code, then a pressure class letter, then the connections listed in port order. On a dual unit the connection list is long because it covers two refrigerant circuits and the water side. Units stamped under the current name read DBD310; it is the same model.

It can usually be cleaned if the fouling is caught early. Brazed units are cleaned in place by circulating a suitable solution through the water side, against the normal flow direction, followed by a thorough flush.

What cannot be fixed is a leak between circuits or channels that are fully blocked, because cleaner only goes where there is flow. A rising water pressure drop at the same flow, or a refrigerant pressure drifting away from normal at the same water conditions, is the early sign. If one circuit is already tripping on its pressure safety, a new unit is normally the quicker repair.

Record every character you can read, in order, with gaps marked. The model and the plate count are the most useful fields, and the last letter before the connection list gives the pressure class.

Then measure the unit: height, width, depth of the plate pack between the cover plates, and the spacing between connection centers. List each connection with its type and size and note which are refrigerant and which are water. Add photos of the front cover and the machine's own data plate. With those we will confirm the configuration.

These models are catalogued alongside the DB310. Each has its own page with its dimensions, materials and part numbers.

SWEP B30 - A cross-flow frame in the 200 to 400 GPM band.