SWEP PI190 brazed plate heat exchanger

SWEP PI190

PRODUCT TYPE STYLE MAX FLOW
Heat Exchanger Brazed Plate Copper Brazed 123.28 GPM

Specifications


Configuration & Size

Plate Dimensions:
524.5 x 202 mm
Port Centres:
460 x 136 mm
Maximum Plates:
140
Channel Volume:
0.149/0.172 dm3
Weight:
6.45 kg plus 0.289 kg per plate
Brand:
SWEP

Materials

  • Plates: 316 stainless steel plates, cover plates 304 stainless steel
  • Braze: copper
  • Connections: Threaded, Victaulic, Solder

Ratings

  • Max Flow: 28 m3/h (123.28 GPM)
  • Approvals: PED; UL; KHK
  • Max Particle Size: 0.8 mm

SWEP PI190 Brazed Plate Heat Exchangers

Single-Circuit Evaporator, 60-150 kW

The SWEP PI190 is a single-circuit evaporator for air-cooled and water-cooled reversible chillers running low-GWP refrigerants. SWEP publishes it for 60 to 150 kW, with a next-generation AsyMatrix plate pattern that raises thermal performance while cutting water-side pressure drop and refrigerant charge.

A mid-size frame sized for reversible chillers. The PI190 measures 524.5 x 202 mm (20.65 x 7.95 in) with port centres at 460 x 136 mm, takes up to 140 plates and has a published maximum flow of 28 m3/h (123.28 GPM).

The PI190 and FI190 cannot be told apart by tape measure. Both have the same 524.5 x 202 mm outline, the same 123.28 GPM ceiling and the same plate and braze materials; the PI190 is the evaporator build. Its AsyMatrix channels are asymmetric - SWEP publishes channel volumes of 0.149 and 0.172 liters for the two sides - so the refrigerant and water circuits are not interchangeable. The selection mistake is ordering by frame size, or piping the unit with the circuits swapped, which costs capacity and raises water-side pressure drop without any visible fault.

316 channel plates, 304 cover plates, copper braze. SWEP publishes threaded, Victaulic and solder connections for the PI190, with PED, UL and KHK approvals. The example designation is PI190H/1P-NSC-H, NSC being the code for 316 channel plates with 304 cover plates and copper braze.

Ordering by the string. Quote a PI190 by its full designation rather than by the model alone - the fields after the model set the plates, materials, pressure class and connections. See the model number guide.



SWEP PI190 brazed plate heat exchanger detail

Best as the evaporator in a 60 to 150 kW reversible chiller charged with a low-GWP refrigerant.

Request a Quote

SWEP PI190 Applications


outline drawing of the SWEP PI190 showing the A x B plate dimensions and C x D port centres

Confirming Fit on a PI190 Replacement

The PI190 measures 524.5 x 202 mm (20.65 x 7.95 in) over the plate pack, with port centres of 460 x 136 mm (18.11 x 5.35 in). Connections on the catalogued builds: Threaded, Victaulic, Solder.

SWEP publishes the weight as 6.45 kg plus 0.289 kg per plate, so the plate count off the nameplate sets what the mounting has to carry.

The outline and port centres have to match, and so do the connection type and size on both the refrigerant and the water ports. Depth grows with plate count, so confirm the plate count before assuming the unit sits the same in its bracket. Because the two channel sides are different, each circuit has to go back on the ports it came off.

Call and talk it through with an engineer: 1-805-484-2992

Before You Order a PI190

SWEP publishes PED, UL and KHK for the PI190. PED is the European pressure equiptment approval, UL is the recognition a North American inspector looks for on a refrigerant-side component, and KHK covers high-pressure gas equipment in Japan.

Two cautions. First, an approval applies to the unit as stamped: the pressure class letter in the designation is a category, and the rating on the nameplate is what governs. Second, ASME and CRN are not on the published list for this model. If the job specification calls for either, say so in the quote request and we will confirm what can be supplied. More on this under Approvals and Certifications.

In place, by circulating a cleaning solution through the water side and rinsing afterward. The unit is brazed and cannot be opened, and the copper braze means the cleaner must be safe for copper as well as stainless steel. Running the solution against the normal flow direction clears deposits faster.

On an evaporator, do not let fouling run. A dirty water side shows as rising water pressure drop and a falling evaporating temperture, and reduced flow through partly blocked channels is how an evaporator ends up freezing locally.

SWEP publishes a maximum particle size of 0.8 mm for the PI190, so the strainer on the water inlet has to stop anything larger than that. That is tighter than the 1 mm published for several other frames, and a strainer carried over from a different exchanger may be too coarse.

The reason is specific to evaporator duty. Debris that lodges at the channel entrances starves those channels of water, the water left in them gets colder than the rest, and it can freeze and split the plate pack. Clean the strainer after commissioning, when pipe scale and weld slag are moving, and again whenever water pressure drop climbs.

Up to 140. There are no catalogued PI190 part numbers on file, so each unit is configured for its duty within SWEP's published 60 to 150 kW range.

More plates lower the water-side pressure drop and tighten the approach, so the evaporating temperature sits closer to the leaving water temperature. The costs are depth, weight - each plate adds 0.289 kg (0.637 lb) - and refrigerant charge, since every added channel holds refrigerant. Past a point, extra plates also slow the refrigerant in each channel and the evaporator becomes less stable at part load. Plate Count and Capacity covers the trade-off.

These models are catalogued alongside the PI190. Each has its own page with its dimensions, materials and part numbers.

SWEP FI190 - Part of the 190 range, designed around R32, R454B and R290.