| Product | Type | Plates | Max Flow |
|---|---|---|---|
| Heat Exchanger | Brazed Plate | 40 | 120.64 GPM |
Note: Unit pictured is representative of standard unit and may not exactly depict p/n V120THx40/1P-SC-M 22U(27)+42U(27)+2x1 1/2"&35.1(27) as shown on this page.
V120THx40/1P-SC-M 22U(27)+42U(27)+2x1 1/2"&35.1(27) designates a SWEP V120T brazed plate heat exchanger with 40 plates in the pack. Its H plates are the high-theta pattern - the choice when the leaving temperature is tight and the pump has head to spare. Reading the string: /1P is single pass; -SC is 316/316L stainless steel plates joined with copper. The closing M is the pressure class: up to 45 bar at 135 C, fatigue tested. Connections are listed as 22U(27)+42U(27)+2x1 1/2"&35.1(27), in port order. The V120T plate pack measures 525 x 243 mm (20.67 x 9.57 in) on 456 x 174 mm port centres, and by SWEP's published weight formula a 40-plate unit comes to about 25.3 kg (55.8 lb) dry. The frame is published to 27.4 m3/h (120.64 GPM) - a port limit rather than a design flow. Check the connection field separately from the plate count: two units can be consistant in every other field and still not pipe up.