| PRODUCT | TYPE | STYLE | MAX FLOW |
|---|---|---|---|
| Heat Exchanger | Brazed Plate | Copper Brazed | 39.63 GPM |
The SWEP V25 is a tall, narrow evaporator with SWEP's V-ring refrigerant distribution system. It is built for demanding cooling duties and also serves as a reversible condenser and as a cascade exchanger in two-phase applications.
Tall and narrow, up to 140 plates. The V25 measures 524 x 116 mm (20.63 x 4.57 in) with port centres of 479 x 72 mm. Maximum plate count is 140 and published max flow is 39.63 GPM (9 m3/h).
The V-ring is the reason to specify a V25. SWEP states that the V-ring distribution system gives optimal evaporator operation in both counter-current and co-current configurations, including with large plate packs. That matters in a reversible machine, where the flows run co-current in one mode. The B25T is published at 526 x 119 mm with 304 plates - close to the V25, but not the same outline and not the same unit. The mistake is fitting a B25T because the plate count and connections look alike; uneven refrigerant feed then shows up as unstable superheat and lost capacity.
Solder and combo connections, class M on file. Published connection styles are threaded and solder; the part numbers on file use 12.8 and 22U refrigerant connections with 2x1"&22U combo water connections. Plates are 316/316L with copper braze (SC), pressure class M on file, and approvals are PED, UL and KHK.
Reading the designation. A V25 is ordered as a full string, for example V25THx50/1P-SC-M 12.8+22U+2x1"&22U. The model number guide decodes each field, and the string off the nameplate - whole or partial - is enough to confirm the build.
Best as a direct-expansion evaporator or reversible condenser where even refrigerant feed matters.
Request a Quote
The V25 measures 524 x 116 mm (20.63 x 4.57 in) over the plate pack, with port centres of 479 x 72 mm (18.86 x 2.83 in). Connections on the catalogued builds: Threaded, Solder.
SWEP publishes the weight as 3.27 kg plus 0.254 kg per plate, so the plate count off the nameplate sets what the mounting has to carry.
Beyond the outline, the port centres must match the existing lines and the depth must suit the space, since the pack gets deeper with each plate. The refrigerant inlet is the port that carries the V-ring distribution, so the unit has to go back in the same orientation with the refrigerant and water on the same ports as before. Match each connection by type and size, including which water connections are combo fittings.
Call and talk it through with an engineer: 1-805-484-2992