| PRODUCT | TYPE | STYLE | MAX FLOW |
|---|---|---|---|
| Heat Exchanger | Brazed Plate | Copper Brazed | 17.61 GPM |
The SWEP E5T is a very compact copper-brazed unit in 316/316L stainless, developed to give maximum heat transfer in wall-hung, non-condensing boiler applications. Its start and end plates are integrated into the pack, so the cover plates take part in heat transfer.
A hand-sized boiler exchanger. The E5T measures 192 x 73 mm (7.56 x 2.87 in), takes up to 41 plates and has a published maximum flow of 4 m3/h (17.61 GPM).
The E is not a B with a different label. The E5T has integrated start and end plates, and its cover plates are used for heat transfer, which gets more duty from a small pack. That makes it narrower than the B-series units on the same frame: the B5T and B5AS are 193 x 76 mm against the E5T's 192 x 73 mm. The E5AS matches the E5T's outline exactly but is an AsyMatrix unit with asymmetric channels, optimized for hot tap water. Ordering by size alone can bring any of these. In a boiler casing a few millimeters and the right port arrangement decide whether the part goes in.
SC material, S pressure class. Part numbers on file are SC - 316/316L plates, copper braze - in the S pressure class. Catalogued connections include 3/4" threaded ports and configurations listed with plain port holes. Published approvals are PED, UL and KHK.
Ordering by the string. Quote a E5T by its full designation, for example E5THx12/1P-SC-S 4xHOLE rather than by the model alone - the fields after the model set the plates, materials, pressure class and connections. See the model number guide.
Best as the plate heat exchanger inside a wall-hung, non-condensing boiler, where space is tightest.
Request a Quote
The E5T measures 192 x 73 mm (7.56 x 2.87 in) over the plate pack, with port centres of 154 x 40 mm (6.06 x 1.57 in). Connections on the catalogued builds: Threaded.
SWEP publishes the weight as 0.29 kg plus 0.04 kg per plate, so the plate count off the nameplate sets what the mounting has to carry.
Inside a boiler the port arrangement matters as much as the outline: some E5T configurations have threaded connections and others are listed with plain port holes for mounting against a manifold, and one will not replace the other. Port centres have to match the boiler's hydraulic block, and depth grows with plate count, so a unit with more plates may not fit the space. Match the plate count on the nameplate unless the boiler maker allows for a different one.
Call and talk it through with an engineer: 1-805-484-2992